Programming Elgar CW-P Series
4-6 Operation Manual
4.3.3 Specify Current Limit Type
This menu item specifies whether the CW will shut down after a delay or fold back
voltage to maintain the presently set current at the output terminals.
CURR SHUT,FOLD
4.3.4 Specify Shutdown Delay
This menu item specifies the amount of time that the CW will fold back before shutting
down when the current is exceeded and the above mode is in shutdown mode. The
range is 0 to 3000 milliseconds.
CDLY nnn (e.g., 200)
4.3.5 Specify Program Keys Locked Mode
This menu item specifies whether the PROGRAM buttons will be operable. When the
PROGRAM buttons are locked, this is the only menu item that operates.
PROG ENA,DIS
4.3.6 Store Present Machine Settings
This menu item, when saved (not cancelled) by the user, will gather up any changes
made while in the menu system and save them along with the present system state to
the dialed in memory location. Valid memory locations are 0 to 98.
STO nn
System Parameters Saved and Recalled:
Volts
Frequency
Current Limit
Current Limit Type (Shut, Fold)
Current Limit Shutdown Time
Voltage Range (Low, High)
Overvoltage
Analog Input on/off
Clock signal direction input/output
Przeglądanie stron 57